- Weight: 11.500 lbs (ca. 5.200 kg)
- Normal Power Speed: 3.600 rpm
TURBINE HYDRAULIC STARTING SYSTEM
- Pump: SAUER SUNDSTRAND A-0034-35089
- Capacity: 56 gpm @ 5.200 psig
- Reservoir Capacity: 40 gal.
- Cooling Pump: SUNDSTRAND SNP2/08 DSC06
- Heat Exchanger: HAYDEN 020671
VENTILATION AND SILENCING
- Air Inlet Filtration System: DONALDSON OSM-AD20404-01
- Housing/Fans: TCF AEROVENT/D-29670-50HZ
- Air Inlet Silencing: DONALDSON 1FA-46984-01
- Turbine Room Silencing: VAW SYSTEM SS4200D1
ALIMENTATION
- Natural Gas: 250 MMBtu/hb, filtered at 3 µ, 355-395 psig, max. 200° F
- Fuel Flow-Control Valve: WOODWARD 8915-775
LUBRICATION SYSTEM
- Reservoir Capacity: 150 gal.
- Supply and Scavenge Filtering: PALL HZ8640
- Heat Exchanger: API BASCO
TURBINE HYDRAULIC SYSTEM
- Prime Mover: Connected to the turbine accessory gearbox
- Relief Valve Setting: 650 psig
- Filtering: PALL HZ8646
FIRE SUPPRESSION AND GAS DETECTION SYSTEM
- Manufacturer: WILSON FIRE UJ822551
- Fire suppression: CO2
- Thermic detectors: 2 at 225° F and 2 at 450° F
- Optic detectors: 4, double frequency infrared
- Gas detector: 3 analogic
TURBINE WATER WASHING SYSTEM
- Pression: 15-65 psig
- Reservoir capacity: 26.5 gal.
MONITORING SYSTEM
- CTR Monitor: XYCOM
- Vibration Monitor: BENTLEY NEVADA
BATTERIES
- Control unit back-up batteries: Nickel-cadmium cell, 24V, capacity 323
- Fire and gas detection batteries: Nickel-cadmium cell, 24V, capacity 56
- Weight: 11.500 lbs (ca. 5.200 kg)
- Normal Power Speed: 3.600 rpm
TURBINE HYDRAULIC STARTING SYSTEM
- Pump: SAUER SUNDSTRAND A-0034-35089
- Capacity: 56 gpm @ 5.200 psig
- Reservoir Capacity: 40 gal.
- Cooling Pump: SUNDSTRAND SNP2/08 DSC06
- Heat Exchanger: HAYDEN 020671
VENTILATION AND SILENCING
- Air Inlet Filtration System: DONALDSON OSM-AD20404-01
- Housing/Fans: TCF AEROVENT/D-29670-50HZ
- Air Inlet Silencing: DONALDSON 1FA-46984-01
- Turbine Room Silencing: VAW SYSTEM SS4200D1
ALIMENTATION
- Natural Gas: 250 MMBtu/hb, filtered at 3 µ, 355-395 psig, max. 200° F
- Fuel Flow-Control Valve: WOODWARD 8915-775
LUBRICATION SYSTEM
- Reservoir Capacity: 150 gal.
- Supply and Scavenge Filtering: PALL HZ8640
- Heat Exchanger: API BASCO
TURBINE HYDRAULIC SYSTEM
- Prime Mover: Connected to the turbine accessory gearbox
- Relief Valve Setting: 650 psig
- Filtering: PALL HZ8646
FIRE SUPPRESSION AND GAS DETECTION SYSTEM
- Manufacturer: WILSON FIRE UJ822551
- Fire suppression: CO2
- Thermic detectors: 2 at 225° F and 2 at 450° F
- Optic detectors: 4, double frequency infrared
- Gas detector: 3 analogic
TURBINE WATER WASHING SYSTEM
- Pression: 15-65 psig
- Reservoir capacity: 26.5 gal.
MONITORING SYSTEM
- CTR Monitor: XYCOM
- Vibration Monitor: BENTLEY NEVADA
BATTERIES
- Control unit back-up batteries: Nickel-cadmium cell, 24V, capacity 323
- Fire and gas detection batteries: Nickel-cadmium cell, 24V, capacity 56